High Temperature 1.6Mpa PTFE Electromagnetic Flow Meter Anti Interference
Advantage:
1). No baffles and running part inside the measuring tube, therefore no additional flow loss and no jams happen. Especially for measuring the flow of solid-liquid object, for example, sewage, mud pulp and CWS (coal water slurry).
|
2). Only liner and electrode have direct contact with the measuring medium, by choosing correct liner and electrode, then the corrosion resistance and wear resistance can be satisfied. Therefore it can be used in kinds of strong acid and alkali in chemical solutions.
|
3). Easy for installation, 5D for front straight pipe, 2D for back straight pipe(D means inner diameter of chosen instrument).
|
4). It has lightning-protection and electricity-protection circuits. The effective, anti-interference circuits apply to all kinds of bad environment.
|
5). It has multi-language interface to satisfy all the users’ requirements.
|
6). It has the function of self-adjustment and self-checking.
|
Electromagnetic flow meter for measuring Heat (Energy)
MTF electromagnetic flow meter also have a function for measuring heat (energy)
(Please inform us when you place orders). it is a kind of metering instrument for measuring
the heat (energy) from heat-conducting fluid which belong to the heat exchange system.
Through carrying high accuracy and stable Platinum resistance (PT1000)as measuring elements, to make the heat(energy)meter has a very excellent
Selectrion of Ground Ring
If the pipe connecting to the meter is insulated,the ground ring is needed, generally
metallic or non-metallic grounding rings or grounding electrode (non-metallic) material is
available to adapt to the corrosion of the measured material.
If the measured medium is abrasive, ground ring with neck should be used to protect
lining material of two sides and to prolong its life.
In order to make the reliable operation of the instrument, and to improve measurement
accuracy, free from outside interference of Send potential,the sensor should have separate
ground wire, and the ground ring of both sides of the sensors should be fitted when the
ground resistance, in the pipe connecting to the sensor or non-metallic pipe, is less than 10Ω.
MTF |
|
|
|
|
|
Divided type |
Integrated |
Explosion- |
Battery |
Heat(energy) type |
|
Accuracy |
±0.2% or ±0.5% |
||||
Diameter |
DN15~dn2400 |
DN15~DN600 |
DN25~DN1400 |
||
Flange |
Comply with GB9119 Standard carbon steel(stainless steel is optional) |
||||
Pressure |
DN15~DN1600 1.0, |
DN15~DN600 1.0, |
DN15~DN600 1.0,1.6,2.5, |
||
Please consult us if you need special pressure |
|||||
Liner |
PTFE,PU,CR,PFA,F46,IR |