Post Offer Free
Nanjing Metlan Measurement Control Instrument Co., Ltd  

Gold Index: 7853

You are here: home  > Thread Type Electromagnetic Flow Meter High Performance for beer

Thread Type Electromagnetic Flow Meter High Performance for beer 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: MTF

 Thread Type Electromagnetic Flow Meter High Performance 

 

Thread Type Electromagnetic Flow Meter High Performance
 

 

 


Extensive Useage


MTF electromagnetic flow meter is, a kind of instrument,used for measuring the flow

conductivity liquid, which is widely used in flow measuring of Metallurgy, Chemical

industry, Paper industry, Environmental protection, Oil industry, Textile industry,

Food industry and City administration, Water works,etc.

 

 


 


Function:


1). It,s high resistance, fast response design can make undistorted collection of

weak signal and fast response to the flow changes. Its range rate can reach 100:1.


2). It has the function of low conductivity measurement.


3). It is the first domestic company that tests full or empty pipe


by adopting capacitance technology, which can avoid wrong alarms.


4). It has the consistency of converter’s interchange, which can avoid input

parameters repeatedly.


5). Wide range of power supply mode is available (DC: 18V-36V/AC: 85V-265V).


6). It is the first domestic company that adopts the function of saving settings before

delivery, which can avoid the loss of the parameters.


7). It adopts the international leading excitation technology, which circuit is simple,

stable, and reliable.


8). It has the function of infrared remote control and button operation so as to make

the operation more convenient.


9). It provides the function of zero correction of sensor and automatic zero adjustment.


10). It has multi-language interface to satisfy all the users’ requirements.


11). It has the function of self-adjustment and self-checking.


12). It has lightning-protection and electricity-protection circuits. The effective,

anti-interference circuits apply to all kinds of bad environment.

 

 


Reminder

 

The selection of the sensor diameter is not the same as the diameter of pipe.This option

applies to the following:

 

A.for Low flow velocity in the pipe and the stable flow rate, to meet the requirements of the instrumentation on the flow rate range,we should increase the flow rate of partial area and

select the sensor diameter smaller than the pipe diameter ,and install another different -

diameter pipe before the sensor.

 

B.In terms of the price, for the magnetic flow meter with large diameter, the larger diameter

you want, you higher price you will pay; for the low flow rate in the pipe and stable parameter,

the selection of small diameter would be better. It will not only make the meter work in good condition but also reduce the cost.
 

 

 

 

 


Main technical parameters

 

Ambient temperature-25---65
Ambient humidity
Medium temperature:-25--80(Note:The temperature is
different for each lining material, please advise when place
order.)
Casing protection level IP65,IP67,IP68
Flow range 0.5 --- 15m/s
Measuring diameter:DN10---DN2400
Electrode material:Standard 316L(other material is optional)
Flange installation:Comply with GB9119,carbon steel(stainless
steel is optional)
Pressure Grade:PN1.0PN1.6PN2.5PN4.0 optional
Accuracy Grade:. Grade,. Grade
Measuring Parameters:instant flow ,instant flow rate
Record parameters : Total flow accumulated, 32 group event
record
Detection and alarm parameters:Pipe empty alarm, Excitation
current detection alarm
Battery capacity detection alarm
Flow curves: Automatically show flow percentage and curves.
Scaled output signal: Unit volume flow pulse

 

 

 


Date sheet
 

MTF
Electromagnetic
flow meter

Divided type

Integrated 
type(IP67)

Explosion-
proof 
integrated

Battery
powered  
type

Heat(energy) type

Accuracy

±0.2%  or ±0.5%

Diameter

DN15~dn2400

DN15~DN600

DN25~DN1400

Flange

Comply with GB9119 Standard carbon steel(stainless steel is optional)

Pressure

DN15~DN1600 1.0,
1.6,2.5,4.0MPa 
DN700~DN2400 0.6,
1.0,1.6MPa

DN15~DN600 1.0,
1.6,2.5,4.0MPa

DN15~DN600 1.0,1.6,2.5,
4.0MPa DN700~DN2400 0.6,
1.0,1.6MPa

Please consult us if you need special pressure

Liner

PTFE,PU,CR,PFA,F46,IR

Conductivity

≥5μs/cm(Please consult us if it is less than ≥5μs/cm)

Electrode

316L,Hastelloy,Ti,Ta,PT-It

Protection Level

IP67(For
sensor, 
IP28 is 
optional)

IP67

IP67

IP68

IP67  IP68

Medium Temperature

-25~180
(Please 
refer to liner
 material)

-25~80(Please 
refer 
to liner material)

-25~180
(Please refer to
 liner material)

Influence of Ambient
 temperature

-25~60<±0.1%/10 or<±0.25%/10

Repetition

≤±0.1%,±0.25%

Analog output Error

≤±0.02mA

Current

≤20m/s

Electrical connection

M20*1.5seal,G1/2,NPT1/2

Output interface

Standard output(4~20mA),Pulse output,RS485,HART,Profibus-PA

 
 
 

bigPhoto
 Mr. Miss. Angel

Tel: 86-25-53266120
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Nanjing Metlan Measurement Control Instrument Co., Ltd [China (Mainland)]


Business Type:Manufacturer
City: Nanjing
Province/State: Jiangsu
Country/Region: China (Mainland)

You May Like:

Product (161)