Thread Type Electromagnetic Flow Meter High Performance
Extensive Useage
MTF electromagnetic flow meter is, a kind of instrument,used for measuring the flow
conductivity liquid, which is widely used in flow measuring of Metallurgy, Chemical
industry, Paper industry, Environmental protection, Oil industry, Textile industry,
Food industry and City administration, Water works,etc.
Function:
1). It,s high resistance, fast response design can make undistorted collection of
weak signal and fast response to the flow changes. Its range rate can reach 100:1.
2). It has the function of low conductivity measurement.
3). It is the first domestic company that tests full or empty pipe
by adopting capacitance technology, which can avoid wrong alarms.
4). It has the consistency of converter’s interchange, which can avoid input
parameters repeatedly.
5). Wide range of power supply mode is available (DC: 18V-36V/AC: 85V-265V).
6). It is the first domestic company that adopts the function of saving settings before
delivery, which can avoid the loss of the parameters.
7). It adopts the international leading excitation technology, which circuit is simple,
stable, and reliable.
8). It has the function of infrared remote control and button operation so as to make
the operation more convenient.
9). It provides the function of zero correction of sensor and automatic zero adjustment.
10). It has multi-language interface to satisfy all the users’ requirements.
11). It has the function of self-adjustment and self-checking.
12). It has lightning-protection and electricity-protection circuits. The effective,
anti-interference circuits apply to all kinds of bad environment.
Reminder
The selection of the sensor diameter is not the same as the diameter of pipe.This option
applies to the following:
A.for Low flow velocity in the pipe and the stable flow rate, to meet the requirements of the instrumentation on the flow rate range,we should increase the flow rate of partial area and
select the sensor diameter smaller than the pipe diameter ,and install another different -
diameter pipe before the sensor.
B.In terms of the price, for the magnetic flow meter with large diameter, the larger diameter
you want, you higher price you will pay; for the low flow rate in the pipe and stable parameter,
the selection of small diameter would be better. It will not only make the meter work in good condition but also reduce the cost.
Main technical parameters
Ambient temperature-25---65
Ambient humidity
Medium temperature:-25--80(Note:The temperature is
different for each lining material, please advise when place
order.)
Casing protection level IP65,IP67,IP68
Flow range 0.5 --- 15m/s
Measuring diameter:DN10---DN2400
Electrode material:Standard 316L(other material is optional)
Flange installation:Comply with GB9119,carbon steel(stainless
steel is optional)
Pressure Grade:PN1.0PN1.6PN2.5PN4.0 optional
Accuracy Grade:. Grade,. Grade
Measuring Parameters:instant flow ,instant flow rate
Record parameters : Total flow accumulated, 32 group event
record
Detection and alarm parameters:Pipe empty alarm, Excitation
current detection alarm
Battery capacity detection alarm
Flow curves: Automatically show flow percentage and curves.
Scaled output signal: Unit volume flow pulse
Date sheet
MTF | |||||
Divided type | Integrated | Explosion- | Battery | Heat(energy) type | |
Accuracy | ±0.2% or ±0.5% | ||||
Diameter | DN15~dn2400 | DN15~DN600 | DN25~DN1400 | ||
Flange | Comply with GB9119 Standard carbon steel(stainless steel is optional) | ||||
Pressure | DN15~DN1600 1.0, | DN15~DN600 1.0, | DN15~DN600 1.0,1.6,2.5, | ||
Please consult us if you need special pressure | |||||
Liner | PTFE,PU,CR,PFA,F46,IR | ||||
Conductivity | ≥5μs/cm(Please consult us if it is less than ≥5μs/cm) | ||||
Electrode | 316L,Hastelloy,Ti,Ta,PT-It | ||||
Protection Level | IP67(For | IP67 | IP67 | IP68 | IP67 IP68 |
Medium Temperature | -25~180 | -25~80(Please | -25~180 | ||
Influence of Ambient | -25~60<±0.1%/10 or<±0.25%/10 | ||||
Repetition | ≤±0.1%,±0.25% | ||||
Analog output Error | ≤±0.02mA | ||||
Current | ≤20m/s | ||||
Electrical connection | M20*1.5seal,G1/2,NPT1/2 | ||||
Output interface | Standard output(4~20mA),Pulse output,RS485,HART,Profibus-PA |